REACTIONTORQUESTATIC SENSING / MT-RTS
Menu
Torque sensorsCalibrated kitsReplacement reviewSensor selection guideQuote / CAD

MT-RTS-FLG / STATIC TORQUE SENSING

Flange-to-Flange Reaction Torque Sensors

Put the measurement in the fixed load path.

Compact dual-flange torque load cells for motor stator fixtures, valve actuator benches and torsion testing. Begin with the bolt pattern and cross-load envelope.

Requested range 0.5–5,000 Nm

Flange-to-flange interface concept; final geometry requires an approved drawing
Interface concept. Not a dimensioned CAD model or product photograph.

DRAWING REVIEW / CONFIGURATION MATRIX

Torque capacity is only the first dimension.

Series selection envelope, not released model specifications. Request the range-specific drawing and measured stiffness/cross-load limits before design release.

Model (MT-RTS-xxx)Rated Torque (Nm / in-lb)Outer Dia. & Bolt Circle (OD / BCD)Center Thru-Bore ID (mm)Torsional Stiffness (Nm/rad)Max Axial Thrust Limit (N)
MT-RTS-FLGSeries / request code0.5–5,000 Nm4.43–44,253.73 in-lbDrawing confirmationSolid or through-hole configurationRange-specific confirmationCombined-load review required

Dual face flanges · drawing-led BCD

Share the complete mating drawing and available envelope.

Motor stator and valve actuator test stands

Include duty cycle, dynamic peaks and the surrounding fixture.

Reference equipment

FUTEK TFF325 / TFF400 / TFF600 · Honeywell QWF · Interface TS

Independent comparison only. Original model identity and principle must be checked.

BEFORE SELECTING THE RANGE

Check the loads the torque channel does not measure.

  • Bolt count, thread, BCD, pilot and face flatness
  • Maximum axial thrust, bending moment and combined loading
  • Fixture stiffness, parasitic torque paths and usable bandwidth

Material and signal targets: 17-4PH stainless or 7075-T6 aluminum; 1.5–2.0 mV/V nominal full-bridge output; CW/CCW calibration. The requested ±0.05–0.1% FS nonlinearity/hysteresis target requires range-specific verification. Temperature effects, excitation, overload, IP rating and cross-axis sensitivity are confirmed per configuration.

MEASURE THE FIXED LOAD PATH

The shaft turns. The sensor stays on the frame.

A Reaction Torque Sensor between a motor or gearbox housing and the fixed frame measures the housing torque without rotating the sensor cable.

For steady-state balance, relate housing torque to shaft torque after accounting for losses and other loads. During acceleration, include rotor inertia and any parallel torque paths. Validate fixture resonance, sensor bandwidth and cross-load limits.

Review fixed-housing vs. rotary measurement ↗
Fixed frame, static flange sensor and motor stator in series; output shaft rotates separately
Load-path concept. The torque sensor body and cable remain stationary; shaft rotation does not pass through the sensor.

ENGINEERING QUESTIONS

Resolve the load path before ordering.

Can a static sensor measure a changing motor load?

Yes, when the sensor remains stationary and the varying housing load is within the complete measurement system bandwidth. Review inertia, losses, resonances and other torque paths before relating it to shaft output.

Is a reference model a guaranteed drop-in replacement?

No. Approve the range-specific mechanical drawing, stiffness, cross-load limits, excitation, sensitivity and connector wiring before a replacement is released.

What comes with the requested calibration?

Request five points in both CW and CCW, the sensor/readout pairing, uncertainty and the traceability chain. The quotation confirms the actual report scope; NIST traceability is not a blanket product certification.

REQUEST QUOTE / CAD

Start with your load and mounting envelope.

Send the installation constraints. We will review the sensor configuration, drawing, calibration scope and commercial quotation.

Prefer email? inquiry@reactiontorque.com

Please send non-confidential specifications first. CAD is supplied for the agreed configuration after engineering review.

Torque sensor engineering request
Calibration & kit options

Budget add-on increments from the project brief, subject to configuration and written quotation. Calibration traceability and uncertainty must be confirmed for the ordered range.

By sending, you agree to our privacy notice. We use your details to respond to this engineering request.

Other torque sensor interfaces